The AWS IoT platform enables devices to connect to the Amazon cloud and lets applications in the cloud interact with Internet-connected things. Common IoT applications either collect and process telemetry from devices or enable users to control a device remotely. Things report their state by publishing messages, in JSON format, on MQTT topics.
|
|
|
|
For more information see this <a href="http://docs.aws.amazon.com/iot/latest/developerguide/iot-dg.pdf" target="_blank"> PDF File </a>.
|
|
|
|
## Getting Started with AWS IoT
|
|
|
|
### Creating the message broker (Amazon website):
|
|
|
|
* Sign in to the [AWS Management Console](https://aws.amazon.com/console/)
|
|
* Navigate to the IoT Console by clicking on the [AWS IoT link](https://github.com/pycom/pycom-docs/tree/37661883902849b1a931ee273a23ae8e0f3d773e/img/aws-1.png)
|
|
* In the left navigation pane, choose [Register/Manage](https://github.com/pycom/pycom-docs/tree/37661883902849b1a931ee273a23ae8e0f3d773e/img/aws-2.png)
|
|
* Click on the create button, give your [device a name and press create](https://github.com/pycom/pycom-docs/tree/37661883902849b1a931ee273a23ae8e0f3d773e/img/aws-3.png)
|
|
* Click on the device that has been created
|
|
* On the Details page, in the left navigation pane, choose [Security](https://github.com/pycom/pycom-docs/tree/37661883902849b1a931ee273a23ae8e0f3d773e/img/aws-4.png)
|
|
* On the Certificates page, choose Create certificate
|
|
* Download all the certificates, then press the Activate and the Attach a Policy buttons. [See image](https://github.com/pycom/pycom-docs/tree/37661883902849b1a931ee273a23ae8e0f3d773e/img/aws-5.png)
|
|
* Click on the Create New Policy button
|
|
* On the [Create Policy](https://github.com/pycom/pycom-docs/tree/37661883902849b1a931ee273a23ae8e0f3d773e/img/aws-6.png) page, choose a policy name and the actions to authorise.
|
|
* Go to the certificates page, click on the three dots of your certificate and attach the policy to the certificate as shown in the [diagram](https://github.com/pycom/pycom-docs/tree/37661883902849b1a931ee273a23ae8e0f3d773e/img/aws-7.png)
|
|
|
|
### Setting up the device (Pycom device):
|
|
|
|
* Download the latest sample code from the Pycom [GitHub Repository](https://github.com/pycom/aws-pycom).
|
|
* Connect to the device via FTP and put the root CA certificate, the client certificate (`*.pem.crt`) and the private key (`*.private.pem.key`) in the `/flash/cert` folder.
|
|
* Update the config file with your WiFi settings, the [AWS Host](https://github.com/pycom/pycom-docs/tree/37661883902849b1a931ee273a23ae8e0f3d773e/img/aws-8.png) and the certificate paths.
|
|
* Put the `config.py` and the `main.py` in the device flash
|
|
|
|
### Configuration (`config.py`):
|
|
|
|
This file contains the WiFi, certificate paths and application specific settings that need to be updated by the user.
|
|
|
|
```python
|
|
|
|
# WiFi configuration
|
|
WIFI_SSID = 'my_wifi_ssid'
|
|
WIFI_PASS = 'my_wifi_password'
|
|
|
|
# AWS general configuration
|
|
AWS_PORT = 8883
|
|
AWS_HOST = 'aws_host_url'
|
|
AWS_ROOT_CA = '/flash/cert/aws_root.ca'
|
|
AWS_CLIENT_CERT = '/flash/cert/aws_client.cert'
|
|
AWS_PRIVATE_KEY = '/flash/cert/aws_private.key'
|
|
|
|
################## Subscribe / Publish client #################
|
|
CLIENT_ID = 'PycomPublishClient'
|
|
TOPIC = 'PublishTopic'
|
|
OFFLINE_QUEUE_SIZE = -1
|
|
DRAINING_FREQ = 2
|
|
CONN_DISCONN_TIMEOUT = 10
|
|
MQTT_OPER_TIMEOUT = 5
|
|
LAST_WILL_TOPIC = 'PublishTopic'
|
|
LAST_WILL_MSG = 'To All: Last will message'
|
|
|
|
####################### Shadow updater ########################
|
|
#THING_NAME = "my thing name"
|
|
#CLIENT_ID = "ShadowUpdater"
|
|
#CONN_DISCONN_TIMEOUT = 10
|
|
#MQTT_OPER_TIMEOUT = 5
|
|
|
|
####################### Delta Listener ########################
|
|
#THING_NAME = "my thing name"
|
|
#CLIENT_ID = "DeltaListener"
|
|
#CONN_DISCONN_TIMEOUT = 10
|
|
#MQTT_OPER_TIMEOUT = 5
|
|
|
|
####################### Shadow Echo ########################
|
|
#THING_NAME = "my thing name"
|
|
#CLIENT_ID = "ShadowEcho"
|
|
#CONN_DISCONN_TIMEOUT = 10
|
|
#MQTT_OPER_TIMEOUT = 5
|
|
```
|
|
|
|
### Subscibe / Publish (`main.py`)
|
|
|
|
To subscribe to a topic:
|
|
|
|
* Go to the AWS Iot page, click on manage and choose your device
|
|
* From the left hand side, choose Activity and then click MQTT client.
|
|
* Choose the [topic name](https://github.com/pycom/pycom-docs/tree/37661883902849b1a931ee273a23ae8e0f3d773e/img/aws-9.png) you entered in the configuration file.
|
|
* Messages should be published as shown in the [diagram](https://github.com/pycom/pycom-docs/tree/37661883902849b1a931ee273a23ae8e0f3d773e/img/aws-10.png)
|
|
|
|
```python
|
|
|
|
# user specified callback function
|
|
def customCallback(client, userdata, message):
|
|
print("Received a new message: ")
|
|
print(message.payload)
|
|
print("from topic: ")
|
|
print(message.topic)
|
|
print("--------------\n\n")
|
|
|
|
# configure the MQTT client
|
|
pycomAwsMQTTClient = AWSIoTMQTTClient(config.CLIENT_ID)
|
|
pycomAwsMQTTClient.configureEndpoint(config.AWS_HOST, config.AWS_PORT)
|
|
pycomAwsMQTTClient.configureCredentials(config.AWS_ROOT_CA, config.AWS_PRIVATE_KEY, config.AWS_CLIENT_CERT)
|
|
|
|
pycomAwsMQTTClient.configureOfflinePublishQueueing(config.OFFLINE_QUEUE_SIZE)
|
|
pycomAwsMQTTClient.configureDrainingFrequency(config.DRAINING_FREQ)
|
|
pycomAwsMQTTClient.configureConnectDisconnectTimeout(config.CONN_DISCONN_TIMEOUT)
|
|
pycomAwsMQTTClient.configureMQTTOperationTimeout(config.MQTT_OPER_TIMEOUT)
|
|
pycomAwsMQTTClient.configureLastWill(config.LAST_WILL_TOPIC, config.LAST_WILL_MSG, 1)
|
|
|
|
#Connect to MQTT Host
|
|
if pycomAwsMQTTClient.connect():
|
|
print('AWS connection succeeded')
|
|
|
|
# Subscribe to topic
|
|
pycomAwsMQTTClient.subscribe(config.TOPIC, 1, customCallback)
|
|
time.sleep(2)
|
|
|
|
# Send message to host
|
|
loopCount = 0
|
|
while loopCount < 8:
|
|
pycomAwsMQTTClient.publish(config.TOPIC, "New Message " + str(loopCount), 1)
|
|
loopCount += 1
|
|
time.sleep(5.0)
|
|
```
|
|
|
|
### Shadow updater (`main.py`)
|
|
|
|
```python
|
|
|
|
# user specified callback functions
|
|
def customShadowCallback_Update(payload, responseStatus, token):
|
|
if responseStatus == "timeout":
|
|
print("Update request " + token + " time out!")
|
|
if responseStatus == "accepted":
|
|
payloadDict = json.loads(payload)
|
|
print("Update request with token: " + token + " accepted!")
|
|
print("property: " + str(payloadDict["state"]["desired"]["property"]))
|
|
if responseStatus == "rejected":
|
|
print("Update request " + token + " rejected!")
|
|
|
|
def customShadowCallback_Delete(payload, responseStatus, token):
|
|
if responseStatus == "timeout":
|
|
print("Delete request " + token + " time out!")
|
|
if responseStatus == "accepted":
|
|
print("Delete request with token: " + token + " accepted!")
|
|
if responseStatus == "rejected":
|
|
print("Delete request " + token + " rejected!")
|
|
|
|
# configure the MQTT client
|
|
pycomAwsMQTTShadowClient = AWSIoTMQTTShadowClient(config.CLIENT_ID)
|
|
pycomAwsMQTTShadowClient.configureEndpoint(config.AWS_HOST, config.AWS_PORT)
|
|
pycomAwsMQTTShadowClient.configureCredentials(config.AWS_ROOT_CA, config.AWS_PRIVATE_KEY, config.AWS_CLIENT_CERT)
|
|
|
|
pycomAwsMQTTShadowClient.configureConnectDisconnectTimeout(config.CONN_DISCONN_TIMEOUT)
|
|
pycomAwsMQTTShadowClient.configureMQTTOperationTimeout(config.MQTT_OPER_TIMEOUT)
|
|
|
|
# Connect to MQTT Host
|
|
if pycomAwsMQTTShadowClient.connect():
|
|
print('AWS connection succeeded')
|
|
|
|
deviceShadowHandler = pycomAwsMQTTShadowClient.createShadowHandlerWithName(config.THING_NAME, True)
|
|
|
|
# Delete shadow JSON doc
|
|
deviceShadowHandler.shadowDelete(customShadowCallback_Delete, 5)
|
|
|
|
# Update shadow in a loop
|
|
loopCount = 0
|
|
while True:
|
|
JSONPayload = '{"state":{"desired":{"property":' + str(loopCount) + '}}}'
|
|
deviceShadowHandler.shadowUpdate(JSONPayload, customShadowCallback_Update, 5)
|
|
loopCount += 1
|
|
time.sleep(5)
|
|
```
|
|
|
|
### Delta Listener (`main.py`)
|
|
|
|
```python
|
|
|
|
# Custom Shadow callback
|
|
def customShadowCallback_Delta(payload, responseStatus, token):
|
|
payloadDict = json.loads(payload)
|
|
print("property: " + str(payloadDict["state"]["property"]))
|
|
print("version: " + str(payloadDict["version"]))
|
|
|
|
# configure the MQTT client
|
|
pycomAwsMQTTShadowClient = AWSIoTMQTTShadowClient(config.CLIENT_ID)
|
|
pycomAwsMQTTShadowClient.configureEndpoint(config.AWS_HOST, config.AWS_PORT)
|
|
pycomAwsMQTTShadowClient.configureCredentials(config.AWS_ROOT_CA, config.AWS_PRIVATE_KEY, config.AWS_CLIENT_CERT)
|
|
|
|
pycomAwsMQTTShadowClient.configureConnectDisconnectTimeout(config.CONN_DISCONN_TIMEOUT)
|
|
pycomAwsMQTTShadowClient.configureMQTTOperationTimeout(config.MQTT_OPER_TIMEOUT)
|
|
|
|
# Connect to MQTT Host
|
|
if pycomAwsMQTTShadowClient.connect():
|
|
print('AWS connection succeeded')
|
|
|
|
deviceShadowHandler = pycomAwsMQTTShadowClient.createShadowHandlerWithName(config.THING_NAME, True)
|
|
|
|
# Listen on deltas
|
|
deviceShadowHandler.shadowRegisterDeltaCallback(customShadowCallback_Delta)
|
|
|
|
# Loop forever
|
|
while True:
|
|